Resources Buyer guide

Solenoid Valve RFQ Data Sheet: From Media Conditions to Comparable Quotes

Build a solenoid valve RFQ data sheet that fixes medium, pressure, flow, materials, voltage and connections so supplier quotes are directly comparable.

Kailing AT-SR Spring Return Pneumatic Actuator

Solenoid Valve RFQ Data Sheet: From Media Conditions to Comparable Quotes

A solenoid valve RFQ is only as strong as the data sheet behind it. When buyers fix the medium, temperature, pressure, flow path, materials and electrical data in the same format, suppliers can quote like-for-like instead of guessing. That is what turns a list of fluid control components into comparable offers.

What a complete RFQ data sheet contains

Field Why it matters Example entry
Medium and concentration Drives body and seal compatibility Water-glycol coolant
Media temperature Sets seal and coil limits -10 to +120 °C
Operating pressure Sets valve construction and rating 0–0.7 MPa water
Orifice / port / CV Sizes the flow path 16 mm orifice, G1/2, CV 4.8
Body and seal Prevents corrosion and seal swelling Stainless steel valve, EPDM seal
Voltage and coil protection Matches control power and environment IP65 square coil; voltage specified in model code
Connection and mounting Matches piping and replacement G1/2, G or NPT
Function Defines the switching task 2/2 normally closed

Step 1 — Define the medium and operating envelope

Start with the fluid, its concentration and the full temperature range, not just the normal case. Then state the pressure range and whether the medium is water, glycol, weak acid, weak alkali or something more aggressive.

The Kailing 2WB160-15-E-S is a 2/2-way, normally closed, direct-acting stainless steel solenoid valve with a 16 mm orifice, G1/2 (DN15) ports, an EPDM diaphragm and an IP65-rated square coil. It is rated for water at 0–0.7 MPa and media temperatures from -10 °C to +120 °C with the EPDM seal.

On larger lines, the Kailing 2WB500-50 is the largest threaded model in the 2WB series of stainless steel fluid solenoid valves: a 2 inch (DN50, G2) direct-acting diaphragm valve with a 50 mm orifice and CV 48, built for pure water, weak acid, weak alkali and mildly corrosive media.

Step 2 — Fix the function and pressure class

State whether the task needs a two-way shut-off valve, a three-way diverter or a vacuum valve, and whether it must open from zero differential. A vacuum line needs a direct-acting valve, because there is no line pressure left to drive a pilot piston or diaphragm. Direct acting means it opens from zero pressure differential - the property a vacuum circuit actually needs.

For packaging machines, the Kailing QX23 is a two-position, three-way direct-acting solenoid valve built for exactly this duty, in a compact L41 x H95 body that slips into tight packaging-machine frames and keeps cycling all shift. Two catalog sizes, QX23-08 (1/4 in) and QX23-10 (3/8 in), cover 0-0.9 MPa with AC 10 W / DC 13 W coils and five voltage references.

For compact vacuum lines, the Kailing VX22 series is a two-position, two-way direct-acting vacuum-type valve that starts from zero pressure differential, with 1.5 to 4.0 mm orifices and 1/8 or 1/4 in ports. The pressure rating steps down as the orifice grows: 0-3.0 MPa at 1.5 mm, 0-1.0 MPa at 4.0 mm.

Step 3 — Size the flow path

Put orifice, port size and CV on the same line so suppliers quote the same hydraulic duty. For example, the 2WB160-15-E-S is a 16 mm orifice, G1/2 (DN15), CV 4.8 valve, while the 2WB500-50 is a 50 mm orifice, G2 (2 in / DN50), CV 48 valve. If the RFQ leaves flow data open, each supplier may assume a different duty and the quotes may not be comparable.

Solenoid Valve RFQ Data Sheet: From Media Conditions to Comparable Quotes

Step 4 — Specify body and seal materials

Name the body material and every wetted seal. The 2WB500-50 uses a 304 stainless steel body (316 on request) with NBR, EPDM, FKM or silicone seals. It is rated for water at 0–0.7 MPa and is offered with AC 220 V or DC 24 V coils as standard.

Flanged lines follow the same rule. The Kailing 2WBF series is a two-way, direct-acting diaphragm valve with flanged ports from 15 to 50, for pure water, weak acid, weak alkali and mildly corrosive media. Sizes run from 15 to 50, normally closed as standard, normally open on selected models. Seals are NBR, EPDM, VITON or silicone, chosen by medium, concentration and temperature.

Step 5 — Electrical data, coil protection and environment

List voltage, frequency, coil power and protection class. The 2WB500-50 is offered with AC 220 V or DC 24 V coils as standard, and its catalog also lists a full voltage range of AC 24/110/220/380 V and DC 12/24/36/110/220 V.

For the 2WB160-15-E-S, the voltage is appended to the model code, for example 2WB160-15-E-S-DC24V. The same RFQ should state the supply, for example DC24 V or AC220 V, and any washdown or humid-room requirement. Where protection class matters, ask suppliers to confirm the coil construction and rating in writing.

Step 6 — Connections and mounting

State thread standard, flange standard and mounting orientation. The 2WB160-15-E-S uses a G1/2 (DN15) port with G or NPT thread. The 2WB500-50 is a threaded model, but the exact thread standard should be confirmed in writing. The 2WBF series covers flanged ports from 15 to 50.

If an existing installation uses a specific standard, say so; otherwise ask suppliers to quote the connection options available for the selected series.

Turn the data sheet into comparable quotes

Ask every supplier to quote against the same line items and to list exceptions line by line. A simple comparison sheet keeps the offers aligned:

Quote column What to check
Model and series Same function and pressure class
Orifice / port / CV Same hydraulic duty
Body and seal Same wetted materials
Voltage and coil Same electrical interface
Connection Same thread or flange standard
Protection class Same environment
Price basis Same quantity and delivery terms

FAQ

What information do I need before requesting a solenoid valve quote?

Medium, concentration, temperature, pressure, orifice or port size, CV, body and seal materials, voltage, connection and protection class. The more of these you fix, the fewer assumptions a supplier has to make.

Which seal should I choose for hot water or glycol?

Match the seal to the medium and temperature. For example, the 2WB160-15-E-S uses an EPDM diaphragm and is rated for water at 0–0.7 MPa and media temperatures from -10 °C to +120 °C with that seal. Always confirm the exact medium and concentration with the supplier.

When is a flanged valve the better choice?

When the line is large, is opened for cleaning, or uses stainless piping where thread roots are undesirable. The 2WBF series covers flanged ports from 15 to 50 for these kinds of duties.

Do vacuum applications need a direct-acting valve?

Yes. A vacuum line does not have enough pressure differential to pilot a valve, so the coil must lift the seal directly. The VX22 series is one example of a direct-acting vacuum valve.

Need a quotation?

Send the page link, quantity, drawings and working conditions to Kailing for review.

Send RFQ →