Resources Buyer guide

Technical Selection Guide: Pneumatic Solenoid Valves, Air Preparation and Standard Cylinders

Engineering guide for selecting 4V directional solenoid valves, F/R/L/FR air-preparation components and SC/SI standard pneumatic cylinders, including flow, bore, mounting and RFQ criteria.

Technical Selection Guide: Pneumatic Solenoid Valves, Air Preparation and Standard Cylinders - Quality test- angle seat valves_1

This document separates pneumatic motion circuits from fluid-control circuits. It focuses on the three groups that appear in most machine-building projects: air-preparation components, directional control valves and standard pneumatic cylinders. The selection sequence is important because the available clean air pressure, filtration quality and flow capacity determine the valve and cylinder performance.

1. Pneumatic motion circuit selection logic

A typical cylinder-control station consists of:

  1. Air-preparation unit: filter, regulator and lubricator or non-lubricated F/R/L/FR combination.
  2. Directional control valve: solenoid-operated 4V/3V or air-pilot 4A/3A valve.
  3. Cylinder: SC tie-rod standard cylinder, SI ISO6431 standard cylinder, or double-shaft/adjustable variants.
  4. Speed control and accessories: flow controls, magnetic switches, fittings and tubing.

Do not select the components independently. The regulator must maintain pressure at the valve inlet; the valve must pass enough air for the required cylinder speed; and the cylinder bore, cushioning and mounting must match the load and motion profile.

2. Start with air quality, pressure stability and flow capacity

The P35 F.R.L air-preparation reference covers F (filter), R (regulator), L (lubricator) and FR combined-series selection. For modern valves and cylinders, verify the complete model code, port size, filtration grade, set pressure and downstream flow requirement before quoting.

Minimum checks:

  • Filter the working air. The 4V directional valve family requires air filtered through 40 microns.
  • Confirm whether the machine uses lubricated air; non-lube designs are often preferred where oil mist is not acceptable.
  • Regulate pressure close to the valve, not only at the compressor.
  • Size the air-preparation port by downstream air consumption, not by the nearest available fitting.
  • Document dew point, oil content and particle requirements when the OEM specifies clean-room, food or instrumentation environments.

3. Select the directional valve by circuit function and flow

The 4V series directional solenoid and pneumatic control valves include 4V solenoid valves, 4A pneumatic control valves, 3V two-position three-way solenoid valves and 3A pneumatic control valves. The series covers 100, 200, 300 and 400 size families.

3.1 Choose valve function first

  • 5-way valve for double-acting cylinder: 4V/4A is normally used to alternately supply and exhaust the cylinder's two chambers.
  • 3-way valve for single-acting cylinder or venting: 3V/3A is suitable for spring-return cylinders, filling, venting and simple pressure switching.
  • Single solenoid: returns to the de-energized position when power is lost.
  • Double solenoid: maintains the last position after signal loss; use when a momentary signal must hold a position.
  • Three-position center options: closed center, exhaust center and pressure center. Select by required behavior between two control signals.
  • Pneumatic control valve: 4A/3A uses air-pilot operation instead of electrical solenoid operation; useful in hazardous areas or where the control medium is pneumatic.

3.2 Match flow to cylinder speed

Published 4V/4A quick-selection data is:

Series Representative models Port Effective area Power
100 4V110, 4V120, 4V130; 4A110, 4A120 M5 or 1/8 in 10 mm² (Cv = 0.56), 7 mm² (Cv = 0.40), 12 mm² (Cv = 0.67) AC 2.5 VA / DC 2.5 W
200 4V210, 4V220, 4V230; 4A210, 4A220, 4A230 1/8 or 1/4 in 14 mm² (Cv = 0.78), 12 mm² (Cv = 0.67), 16 mm² (Cv = 0.89) AC 4.5 VA / DC 3 W
300 4V310, 4V320, 4V330; 4A310, 4A320, 4A330 1/4 or 3/8 in 25 mm² (Cv = 1.40), 18 mm² (Cv = 1.00), 30 mm² (Cv = 1.68) AC 4.5 VA / DC 3 W
400 4V410, 4V420, 4V430; 4A410, 4A420, 4A430 1/2 in 50 mm² (Cv = 2.79), 30 mm² (Cv = 1.68) AC 4.5 VA / DC 3 W

General rule: 100 series suits compact circuits; 200 and 300 series suit common equipment valve stations; 400 series is used when 1/2-inch port capacity is needed. After choosing the port, confirm that the effective area can deliver the required cylinder speed with the actual pressure, tubing length and fittings.

3.3 Confirm valve operating limits

Published family limits for the 4V series are:

  • Working medium: air filtered through 40 microns
  • Action: internal pilot
  • Working pressure: 0.15–0.8 MPa
  • Maximum pressure: 1.2 MPa
  • Working temperature: 5–50 °C
  • Voltage tolerance: ±10%
  • Protection: F-class insulation, IP65
  • Maximum operating frequency: 5 cycles/s
  • Minimum excitation time: 0.05 s

Select wiring type—standard terminal, LED terminal or lead-wire—and thread standard G/ZG/NPT before ordering. Voltage options include DC12V, DC24V, AC24V, AC110V, AC220V and AC380V; the actual control-cabinet voltage and connector standard must be confirmed.

4. Size the cylinder bore by force and speed

The theoretical cylinder force is:

F = p × A

where p is effective differential pressure at the cylinder and A is the piston area. In real projects, include:

  • Load weight and friction
  • Required acceleration and deceleration
  • Guide friction and side load
  • Back pressure through the valve and exhaust circuit
  • Duty cycle and heat buildup
  • A practical safety margin

Do not choose bore from pipe size or visual similarity to another machine. Confirm pressure at the cylinder, not only at the compressor.

5. SC tie-rod standard cylinder selection

The SC series tie-rod standard pneumatic cylinder family includes SC standard, SCD double-shaft double-acting and SCJ double-shaft adjustable variants.

Published family data:

Parameter Value
Bore range 32, 40, 50, 63, 80, 100, 125, 160, 200 mm
Working medium Air
Action Double acting
Pressure range 1.0–9.0 kgf/cm²
Proof pressure 13.5 kgf/cm²
Temperature range −5 to +70 °C
Speed range 30–800 mm/s
Cushioning Adjustable cushion
Ports G1/8–G3/4 by bore

Mounting options include basic, LB foot, FA/FB flange, CA/CB rear clevis and TC/TC-M trunnion. Magnet option S supports magnetic switches; blank means no magnet. Standard-stroke references vary by bore—for example, 25–500 mm for Ø32 and 25–1000 mm for Ø50–Ø200, with larger allowable strokes listed. Always confirm the exact stroke, mounting accessory and port thread from the selected model.

6. SI ISO6431 standard cylinder selection

The SI series ISO6431 standard pneumatic cylinder family includes SI standard double-acting cylinders, SID double-shaft double-acting types and SIJ double-shaft stroke-adjustable types.

Published family data:

Parameter Value
Standard ISO6431
Bore range 32–200 mm
Working medium Air
Pressure range 0.1–0.9 MPa
Proof pressure 1.35 MPa
Temperature range −5 to +70 °C
Speed range 50–800 mm/s
Cushioning Adjustable cushion
Ports G1/8–G1/2 by bore

The catalog lists piston rod diameters by bore—for example Ø12 for Ø32, Ø20 for Ø50/Ø63, Ø25 for Ø80/Ø100 and Ø40 for Ø160/Ø200. SIJ adjustment-stroke references include 25, 50 and 75 mm. Mounting options include basic, LB foot, FA/FB flange, CA/CB rear clevis and TC/TC-M trunnion.

Do not assume SI and DNC cylinders are directly interchangeable. Both are ISO-standard families, but body style, order code, dimensions, cushioning and sensor requirements must be checked against the existing machine drawing.

7. Cylinder-to-valve compatibility checklist

Before final selection, verify:

  1. Cylinder bore and required stroke
  2. Working pressure at the cylinder and available supply pressure
  3. Required speed and cycle frequency
  4. Load direction, side load and guide design
  5. Cushioning requirement
  6. Magnet and switch type
  7. Mounting style and rod-end detail
  8. Port thread standard
  9. Valve function: 3/2, 5/2 or 5/3
  10. Control method: solenoid or air pilot
  11. Valve size, Cv/effective area and pressure drop
  12. Voltage, wiring and connector type
  13. Air-preparation port size, filtration grade and regulator setting

8. RFQ information for exact quoting

For OEM or replacement projects, send:

  • Existing model code, photos and nameplate
  • Cylinder series, bore, stroke and mounting
  • Magnet/switch and rod-end requirement
  • Working pressure, speed and cycle frequency
  • Valve model, function, voltage, wiring, thread standard and mounting type
  • Air-preparation model, port size and pressure setting
  • Environment, temperature and IP or connector requirements
  • Quantity and target delivery

This avoids quoting by family range and allows the exact model, drawings and accessories to be confirmed.

Product references

Contact: sales@kailingfluid.com | +86 574 8888 2522

Need a quotation?

Send the page link, quantity, drawings and working conditions to Kailing for review.